- Network Working Group T. Cox
- Request for Comments: 1407 K. Tesink
- Obsoletes: 1233 Bell Communications Research
- Editors
- January 1993
-
-
- Definitions of Managed Objects
- for the DS3/E3 Interface Type
-
- Status of this Memo
-
- This RFC specifies an IAB standards track protocol for the Internet
- community, and requests discussion and suggestions for improvements.
- Please refer to the current edition of the "IAB Official Protocol
- Standards" for the standardization state and status of this protocol.
- Distribution of this memo is unlimited.
-
- Abstract
-
- This memo defines an extension to the Management Information Base
- (MIB) for use with network management protocols in TCP/IP-based
- internets. In particular, it defines objects for managing DS3 and E3
- Interfaces. This document is a companion document with Definitions
- of Managed Objects for the DS1 Interface Type.
-
- This document entirely replaces RFC 1233, which contains a
- fundamental error: many objects are encoded as Counters that must be
- encoded as INTEGERs or Gauges. The magnitude of the change required
- is sufficient that virtually every object changed. Therefore, the
- MIB documented in RFC 1233 should not be implemented.
-
- Table of Contents
-
- 1. The Network Management Framework ...................... 2
- 2. Objects ............................................... 2
- 2.1 Format of Definitions ................................ 3
- 2.2 Changes from RFC 1233 ................................ 3
- 3. Overview .............................................. 5
- 3.1 Binding between ifIndex and DS3/E3 Interfaces ........ 5
- 3.2 Objectives of this MIB Module ........................ 7
- 3.3 DS3/E3 Terminology ................................... 7
- 3.3.1 Error Events ....................................... 7
- 3.3.2 Performance Parameters ............................. 8
- 3.3.3 Performance Defects ................................ 10
- 3.3.4 Other Terms ........................................ 11
- 4. Object Definitions .................................... 12
- 4.1 The DS3/E3 Near End Group ............................ 12
-
-
-
- Trunk MIB Working Group [Page 1]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- 4.1.1 The DS3/E3 Configuration ........................... 12
- 4.1.2 The DS3/E3 Current ................................. 18
- 4.1.3 The DS3/E3 Interval ................................ 21
- 4.1.4 The DS3/E3 Total ................................... 25
- 4.2 The DS3 Far End Group ................................ 29
- 4.2.1 The DS3 Far End Configuration ...................... 29
- 4.2.2 The DS3 Far End Current ............................ 31
- 4.2.3 The DS3 Far End Interval ........................... 34
- 4.2.4 The DS3 Far End Total .............................. 36
- 4.3 The DS3/E3 Fractional Group .......................... 38
- 5. Acknowledgments ....................................... 41
- 6. References ............................................ 41
- 7. Security Considerations ............................... 43
- 8. Authors' Addresses .................................... 43
-
- 1. The Network Management Framework
-
- The Internet-standard Network Management Framework consists of three
- components. They are:
-
- STD 16/RFC 1155 which defines the SMI, the mechanisms used for
- describing and naming objects for the purpose of management. STD
- 16/RFC 1212 defines a more concise description mechanism, which is
- wholly consistent with the SMI.
-
- RFC 1156 which defines MIB-I, the core set of managed objects for
- the Internet suite of protocols. STD 17/RFC 1213, defines MIB-II,
- an evolution of MIB-I based on implementation experience and new
- operational requirements.
-
- STD 15/RFC 1157 which defines the SNMP, the protocol used for
- network access to managed objects.
-
- The Framework permits new objects to be defined for the purpose of
- experimentation and evaluation.
-
- 2. Objects
-
- Managed objects are accessed via a virtual information store, termed
- the Management Information Base or MIB. Objects in the MIB are
- defined using the subset of Abstract Syntax Notation One (ASN.1) [7]
- defined in the SMI. In particular, each object has a name, a syntax,
- and an encoding. The name is an object identifier, an
- administratively assigned name, which specifies an object type. The
- object type together with an object instance serves to uniquely
- identify a specific instantiation of the object. For human
- convenience, we often use a textual string, termed the OBJECT
- DESCRIPTOR, to also refer to the object type.
-
-
-
- Trunk MIB Working Group [Page 2]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- The syntax of an object type defines the abstract data structure
- corresponding to that object type. The ASN.1 language is used for
- this purpose. However, the SMI [3] purposely restricts the ASN.1
- constructs which may be used. These restrictions are explicitly made
- for simplicity.
-
- The encoding of an object type is simply how that object type is
- represented using the object type's syntax. Implicitly tied to the
- notion of an object type's syntax and encoding is how the object type
- is represented when being transmitted on the network. The SMI
- specifies the use of the basic encoding rules of ASN.1 [8], subject
- to the additional requirements imposed by the SNMP.
-
- 2.1. Format of Definitions
-
- Section 4 contains contains the specification of all object types
- contained in this MIB module. The object types are defined using the
- conventions defined in the SMI, as amended by the extensions
- specified in STD 16, RFC 1212 [13].
-
- 2.2. Changes from RFC 1233
-
- This MIB obsoletes RFC 1233. The changes from RFC 1233 are the
- following:
-
- -- This MIB module contains information to manage
- an E3 interface, also.
-
- -- This MIB module contains three groups:
- DS3/E3 Near End Group which is mandatory,
- DS3 Far End Group which is optional, and
- DS3 Fractional Group which is optional.
-
- -- The DS3 Far End Group is a new group and contains
- configuration information and statistics
- that are collected from the far end DS3/E3 interface.
- Presently, the Far End Group may only be implemented by
- DS3 systems that use C-bit Parity or SYNTRAN.
-
- -- The DS3 Fractional Group is a new group and is
- modeled after the DS1 Fractional Group.
-
- -- ds3CSUIndex has been redefined and renamed
- to dsx3LineIndex. This object
- is the identifier of a DS3/E3 Interface on a device.
- On a CSU, a single DS3/E3 data stream will cross two DS3/E3
- interfaces, which have separate dsx3LineIndex values.
-
-
-
-
- Trunk MIB Working Group [Page 3]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- -- ds3Index has been redefined and renamed to
- dsx3IfIndex. This value for this
- object is equal to the value of ifIndex from the Interfaces
- table of MIB II (STD 17, RFC 1213).
-
- -- The ACCESS for objects in the dsx3ConfigTable has
- been set to read-write for items that are configurable.
-
- -- The dsx3ZeroCoding has been renamed to dsx3LineCoding.
-
- -- A new object has been added called dsx3LoopbackConfig,
- which better describes the loopback capabilities of
- a DS3/E3 interface on a device.
-
- -- The dsx3SendCode object has been updated to reflect
- different types of loopback messages.
-
- -- A new object has been added called dsx3LineStatus.
- This object better describes the status (e.g.,
- failure state and loopback state) of a
- DS3/E3 interface.
-
- -- A new object has been added called dsx3TransmitClockSource.
- This object identifies the source for the transmit clock.
-
- -- All Counters have been changed to Gauges.
-
- -- A Line Errored Seconds object has been added to
- all near end tables.
-
- -- Line Coding Violations are counted instead of Bipolar
- Violations.
-
- -- A new Coding Violation counter has been added to count
- coding violations reported via the C-bits of SYNTRAN
- and C-bit Parity DS3 applications.
- The original Coding Violation counter has been renamed
- to PCV to mean coding violations reported via the P-bits.
- This count is also added for symmetry with the far end
- statistics.
-
- -- A new Errored Second counter and Severely Errored Second
- counter has been added to count these performance events
- via the C-bits of the SYNTRAN and C-bit Parity DS3
- applications. The original ES and SES counters have been
- renamed to PES and PSES to mean reported via the P-bits.
- These counts are also added for symmetry with the far end
- statistics.
-
-
-
- Trunk MIB Working Group [Page 4]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- 3. Overview
-
- These objects are used when the particular media being used to
- realize an interface is a DS3/E3 interface. At present, this applies
- to these values of the ifType variable in the Internet-standard MIB:
-
- ds3 (30)
-
- The DS3 definitions contained herein are based on the DS3
- specifications in ANSI T1.102-1987, ANSI T1.107-1988, ANSI T1.107a-
- 1990, and ANSI T1.404-1989 [9,10,10a,11]. The E3 definitions
- contained herein are based on the E3 specifications in CCITT G.751
- [14].
-
- 3.1. Binding between ifIndex and DS3/E3 Interfaces
-
- Different physical configurations for the support of SNMP with DS3/E3
- equipment exist. To accommodate these scenarios, two different
- indices for DS3/E3 interfaces are introduced in this MIB. These
- indices are dsx3IfIndex and dsx3LineIndex.
-
- External interface scenario: the SNMP Agent represents all managed
- DS3/E3 lines as external interfaces (for example, an Agent residing
- on the device supporting DS3/E3 interfaces directly):
-
- For this scenario, all interfaces are assigned an integer value equal
- to ifIndex, and the following applies:
-
- ifIndex=dsx3IfIndex=dsx3LineIndex for all interfaces.
-
- The dsx3IfIndex column of the DS3/E3 Configuration table relates each
- DS3/E3 interface to its corresponding interface (ifIndex) in the
- Internet-standard MIB (MIB-II STD 17, RFC 1213).
-
- External&Internal interface scenario: the SNMP Agents resides on an
- host external from the device supporting DS3/E3 interfaces (e.g., a
- router). The Agent represents both the host and the DS3/E3 device.
- The index dsx3LineIndex is used to not only represent the DS3/E3
- interfaces external from the host/DS3/E3-device combination, but also
- the DS3/E3 interfaces connecting the host and the DS3/E3 device. The
- index dsx3IfIndex is always equal to ifIndex.
-
- Example:
-
- A shelf full of CSUs connected to a Router. An SNMP Agent residing on
- the router proxies for itself and the CSU. The router has also an
- Ethernet interface:
-
-
-
-
- Trunk MIB Working Group [Page 5]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- +-----+
- | | |
- | | | +---------------------+
- |E | | 44.736 MBPS | ds3 M13 Line#A | ds3 C-bit Parity
- |t | R |---------------+ - - - - - - - - - +------>
- |h | | | |
- |e | O | 44.736 MBPS | ds3 M13 Line#B | ds3 C-bit Parity
- |r | |---------------+ - - - - - - - - - - +------>
- |n | U | | |
- |e | | 44.736 MBPS | ds3 M13 Line#C | ds3 C-bit Parity
- |t | T |---------------+ - - - -- -- - - - - +------>
- | | | | |
- |-----| E | 44.736 MBPS | ds3 M13 Line#D | ds3 C-bit Parity
- | | |---------------+ - - - - -- - - - - +------>
- | | R | |_____________________|
- | | |
- | +-----+
-
- The assignment of the index values could for example be:
-
- ifIndex (= dsx3IfIndex) dsx3LineIndex
-
- 1 NA NA (Ethernet)
- 2 Line#A Router Side 6
- 2 Line#A Network Side 7
- 3 Line#B Router Side 8
- 3 Line#B Network Side 9
- 4 Line#C Router Side 10
- 4 Line#C Network Side 11
- 5 Line#D Router Side 12
- 5 Line#D Network Side 13
-
- For this example, ifNumber is equal to 5. Note the following
- description of dsx3LineIndex: the dsx3LineIndex identifies a DS3/E3
- Interface on a managed device. If there is an ifEntry that is
- directly associated with this and only this DS3/E3 interface, it
- should have the same value as ifIndex. Otherwise, number the
- dsx3LineIndices with an unique identifier following the rules of
- choosing a number greater than ifNumber and numbering inside
- interfaces (e.g., equipment side) with even numbers and outside
- interfaces (e.g., network side) with odd numbers.
-
- If the CSU shelf is managed by itself by a local SNMP Agent, the
- situation would be:
-
-
-
-
-
-
-
- Trunk MIB Working Group [Page 6]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- ifIndex (= dsx3IfIndex) dsx3LineIndex
-
- 1 Line#A Network Side 1
- 2 Line#A RouterSide 2
- 3 Line#B Network Side 3
- 4 Line#B RouterSide 4
- 5 Line#C Network Side 5
- 6 Line#C Router Side 6
- 7 Line#D Network Side 7
- 8 Line#D Router Side 8
-
- 3.2. Objectives of this MIB Module
-
- There are numerous things that could be included in a MIB for DS3/E3
- signals: the management of multiplexors, CSUs, DSUs, and the like.
- The intent of this document is to facilitate the common management of
- all devices with DS3/E3 interfaces. As such, a design decision was
- made up front to very closely align the MIB with the set of objects
- that can generally be read from DS3/E3 devices that are currently
- deployed.
-
- 3.3. DS3/E3 Terminology
-
- The terminology used in this document to describe error conditions on
- a DS3 interface as monitored by a DS3 device are based on the
- definitions from the ANSI T1M1.3/92-005R1 draft standard [12]. If
- the definition in this document does not match the definition in the
- ANSI T1M1.3/92-005R1 draft document, the implementer should follow
- the definition described in this document.
-
- 3.3.1. Error Events
-
- Bipolar Violation (BPV) Error Event
- A bipolar violation error event, for B3ZS(HDB3)-coded
- signals, is the occurrence of a pulse of the same polarity
- as the previous pulse without being part of the zero
- substitution code, B3ZS(HDB3). For B3ZS(HDB3)-coded
- signals, a bipolar violation error event may also include
- other error patterns such as: three(four) or more
- consecutive zeros and incorrect polarity.
-
- Excessive Zeros (EXZ) Error Event
- An EXZ is the occurrence of any zero string length equal
- to or greater than 3 for B3ZS, or greater than 4 for HDB3.
-
- Line Coding Violation (LCV) Error Event
- This parameter is a count of both BPVs and EXZs
- occurring over the accumulation period. An EXZ
-
-
-
- Trunk MIB Working Group [Page 7]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- increments the LCV by one regardless of the length
- of the zero string.
-
- P-bit Coding Violation (PCV) Error Event
- For all DS3 applications, a coding violation error
- event is a P-bit
- Parity Error event. A P-bit Parity Error event is the
- occurrence of a received P-bit code on the DS3 M-frame
- that is not identical to the corresponding locally-
- calculated code.
-
- C-bit Coding Violation (CCV) Error Event
- For C-bit Parity and SYNTRAN DS3 applications, this is
- the count of coding violations reported via the C-bits.
- For C-bit Parity, it is a count of CP-bit parity errors
- occurring in the accumulation interval. For SYNTRAN, it
- is a count of CRC-9 errors occurring in the accumulation
- interval.
-
- 3.3.2. Performance Parameters
-
- All performance parameters are accumulated in fifteen minute
- intervals and up to 96 intervals (24 hours worth) are kept by an
- agent. Fewer than 96 intervals of data will be available if the
- agent has been restarted within the last 24 hours. In addition,
- there is a rolling 24-hour total of each performance parameter.
-
- There is no requirement for an agent to ensure fixed relationship
- between the start of a fifteen minute interval and any wall clock;
- however some agents may align the fifteen minute intervals with
- quarter hours.
-
- Line Errored Seconds (LES)
- A Line Errored Second is a second in
- which one or more CVs occurred OR one or more LOS defects.
-
- P-bit Errored Seconds (PES)
- An PES is a second with one or more PCVs OR
- one or more Out of Frame defects OR a detected incoming AIS.
- This gauge is not incremented when UASs are counted.
-
- P-bit Severely Errored Seconds (PSES)
- A PSES is a second with 44 or more PCVs OR
- one or more Out of Frame defects OR a detected incoming AIS.
- This gauge is not incremented when UASs are counted.
-
- C-bit Errored Seconds (CES)
- An CES is a second with one or more CCVs OR
-
-
-
- Trunk MIB Working Group [Page 8]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- one or more Out of Frame defects OR a detected incoming AIS.
- This count is only for the SYNTRAN and C-bit Parity DS3
- applications. This gauge is not incremented when UASs are
- counted.
-
- C-bit Severely Errored Seconds (CSES)
- A CSES is a second with 44 or more CCVs OR
- one or more Out of Frame defects OR a detected incoming AIS.
- This count is only for the SYNTRAN and C-bit Parity DS3
- applications. This gauge is not incremented when UASs
- are counted.
-
- Severely Errored Framing Seconds (SEFS)
- A SEFS is a second with one or more Out of Frame defects
- OR a detected incoming AIS.
-
- Unavailable Seconds (UAS)
- UAS are calculated by counting the number of seconds that
- the interface is unavailable. The DS3 interface is said
- to be unavailable from the onset of 10 contiguous PSESs, or
- the onset of the condition leading to a failure (see Failure
- States). If the condition leading to the failure was
- immediately preceded by one or more contiguous PSESs, then
- the DS3 interface unavailability starts from the onset of
- these PSESs. Once unavailable, and if no failure is
- present, the DS3 interface becomes available at the onset
- of 10 contiguous seconds with no PSESs. Once unavailable,
- and if a failure is present, the DS3 interface becomes
- available at the onset of 10 contiguous seconds with no
- PSESs, if the failure clearing time is less than
- or equal to 10 seconds. If the failure clearing time is
- more than 10 seconds, the DS3 interface becomes available
- at the onset of 10 contiguous seconds with no PSESs, or
- the onset period leading to the successful clearing
- condition, whichever occurs later. With respect to the
- DS3 error counts, all counters are incremented
- while the DS3 interface is deemed available. While the
- interface is deemed unavailable, the only count that is
- incremented is UASs.
-
- A special case exists when the 10 or more second period
- crosses the 900 second statistics window boundary, as the
- foregoing description implies that the PSES and UAS
- counters must be adjusted when the Unavailable Signal
- State is entered. Clearly, successive GETs of the
- affected dsx3IntervalPSESs and dsx3IntervalUASs objects
- will return differing values if the first GET occurs
- during the first few seconds of the window. This is
-
-
-
- Trunk MIB Working Group [Page 9]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- viewed as an unavoidable side-effect of selecting the
- presently defined managed objects as a basis for this
- memo.
-
- 3.3.3. Performance Defects
-
- Failure States:
- The Remote Alarm Indication (RAI) failure, in SYNTRAN
- applications, is declared after detecting
- the Yellow Alarm Signal on the alarm channel. See ANSI
- T1.107a-1990 [10]. The Remote Alarm Indication failure,
- in C-bit Parity DS3 applications, is declared
- as soon as the preqsence of either one or two alarm signals
- are detected on then Far End Alarm Channel. See [10].
- The Remote Alarm Indication failure may also be declared
- after detecting the far-end SEF/AIS defect (aka yellow).
- The Remote Alarm Indication failure is cleared as soon as
- the presence of the any of the above alarms are removed.
-
- Also, the incoming failure state is declared when a defect
- persists for at least 2-10 seconds. The defects are
- the following: Loss of Signal (LOS), an Out of Frame (OOF)
- or an incoming Alarm Indication Signal (AIS).
- The Failure State is cleared when the defect is absent
- for less than or equal to 20 seconds.
-
- Far End SEF/AIS defect (aka yellow)
- A Far End SEF/AIS defect is the occurrence of the two X-bits
- in a M-frame set to zero. The Far End SEF/AIS defect is
- terminated when the two X-bits in a M-frame are set to
- one.
-
- Out of Frame (OOF) defect
- A DS3 OOF defect is detected when any three or more errors
- in sixteen or fewer consecutive F-bits occur within a DS3
- M-frame. An OOF defect may also be called a Severely
- Errored Frame (SEF) defect. An OOF defect is cleared when
- reframe occurs. A DS3 Loss of Frame (LOF) failure is
- declared when the DS3 OOF defect is consistent for 2 to 10
- seconds. The DS3 OOF defect ends when reframe occurs.
- The DS3 LOF failure is cleared when the DS3 OOF
- defect is absent for 10 to 20 seconds.
-
- An E3 OOF defect is detected when four consecutive frame
- alignment signals have been incorrectly received in there
- predicted positions in an E3 signal. E3 frame alignment
- occurs when the presence of three consecutive frame
- alignment signals have been detected.
-
-
-
- Trunk MIB Working Group [Page 10]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- Loss of Signal (LOS) defect
- The DS3 LOS defect is declared upon observing 175 +/- 75
- contiguous pulse positions with no pulses of either
- positive or negative polarity.
- The DS3 LOS defect is terminated upon observing an average
- pulse density of at least 33% over a period of 175 +/- 75
- contiguous pulse positions starting with the receipt of a
- pulse.
-
- Alarm Indication Signal (AIS) defect
- The DS3 AIS is framed with "stuck stuffing." This implies
- that it has a valid M-subframe alignments bits, M-frame
- alignment bits, and P bits. The information bits are set
- to a 1010... sequence, starting with a one (1) after each
- M-subframe alignment bit, M-frame alignment bit, X bit, P
- bit, and C bit. The C bits are all set to zero giving
- what is called "stuck stuffing." The X bits are set to
- one. The DS3 AIS defect is declared after DS3 AIS is
- present in contiguous M-frames for a time equal to or
- greater than T, where 0.2 ms <= T <= 100 ms.
- The DS3 AIS defect is terminated after AIS is absent in
- contiguous M-frames for a time equal to or greater than T.
-
- The E3 binary content of the AIS is nominally a continuous
- stream of ones. AIS detection and the application of
- consequent actions, should be completed within a time
- limit of 1 ms.
-
- 3.3.4. Other Terms
-
- Circuit Identifier
- This is a character string specified by the circuit
- vendor, and is useful when communicating with the vendor
- during the troubleshooting process.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Trunk MIB Working Group [Page 11]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- 4. Object Definitions
-
- RFC1407-MIB DEFINITIONS ::= BEGIN
-
- IMPORTS
- Gauge
- FROM RFC1155-SMI
- DisplayString, transmission
- FROM RFC1213-MIB
- OBJECT-TYPE
- FROM RFC-1212;
-
- -- This MIB module uses the extended OBJECT-TYPE macro
- -- as defined in RFC 1212.
-
- ds3 OBJECT IDENTIFIER ::= { transmission 30 }
-
-
- -- The DS3/E3 Near End Group
-
- -- Implementation of this group is mandatory for all
- -- systems that attach to a DS3/E3 Interface.
-
- -- The DS3/E3 Near End Group consists of four tables:
- -- DS3/E3 Configuration
- -- DS3/E3 Current
- -- DS3/E3 Interval
- -- DS3/E3 Total
-
- -- the DS3/E3 Configuration
-
- dsx3ConfigTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3ConfigEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3/E3 Configuration table."
- ::= { ds3 5 }
-
- dsx3ConfigEntry OBJECT-TYPE
- SYNTAX Dsx3ConfigEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3/E3 Configuration table."
- INDEX { dsx3LineIndex }
- ::= { dsx3ConfigTable 1 }
-
-
-
-
- Trunk MIB Working Group [Page 12]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- Dsx3ConfigEntry ::=
- SEQUENCE {
- dsx3LineIndex
- INTEGER,
- dsx3IfIndex
- INTEGER,
- dsx3TimeElapsed
- INTEGER,
- dsx3ValidIntervals
- INTEGER,
- dsx3LineType
- INTEGER,
- dsx3LineCoding
- INTEGER,
- dsx3SendCode
- INTEGER,
- dsx3CircuitIdentifier
- DisplayString,
- dsx3LoopbackConfig
- INTEGER,
- dsx3LineStatus
- INTEGER,
- dsx3TransmitClockSource
- INTEGER
- }
-
- dsx3LineIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "This object is the identifier of a DS3/E3
- Interface on a managed device. If there is an
- ifEntry that is directly associated with this
- and only this DS3/E3 interface, it should have
- the same value as ifIndex. Otherwise, number
- the dsx3LineIndices with an unique identifier
- following the rules of choosing a number that
- is greater than ifNumber and numbering the
- inside interfaces (e.g., equipment side) with
- even numbers and outside interfaces (e.g,
- network side) with odd numbers."
- ::= { dsx3ConfigEntry 1 }
-
- dsx3IfIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
-
-
-
- Trunk MIB Working Group [Page 13]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- DESCRIPTION
- "This value for this object is equal to the
- value of ifIndex from the Interfaces table of
- MIB II (RFC 1213)."
- ::= { dsx3ConfigEntry 2 }
-
- dsx3TimeElapsed OBJECT-TYPE
- SYNTAX INTEGER (0..899)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of seconds that have elapsed since
- the beginning of the near end current error-
- measurement period."
- ::= { dsx3ConfigEntry 3 }
-
- dsx3ValidIntervals OBJECT-TYPE
- SYNTAX INTEGER (0..96)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of previous near end intervals for
- which valid data was collected. The value will be
- 96 unless the interface was brought online within
- the last 24 hours, in which case the value will be
- the number of complete 15 minute near end
- intervals since the interface has been online."
- ::= { dsx3ConfigEntry 4 }
-
- dsx3LineType OBJECT-TYPE
- SYNTAX INTEGER {
- dsx3other(1),
- dsx3M23(2),
- dsx3SYNTRAN(3),
- dsx3CbitParity(4),
- dsx3ClearChannel(5),
- e3other(6),
- e3Framed(7),
- e3Plcp(8)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This variable indicates the variety of DS3 C-bit
- or E3 application
- implementing this interface. The type of
- interface affects the interpretation of the
- usage and error statistics.
-
-
-
- Trunk MIB Working Group [Page 14]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- The rate of DS3 is 44.736 Mbps and E3 is
- 34.368 Mbps.
- The dsx3ClearChannel value means that the C-bits
- are not used except for sending/receiving
- AIS.
-
- The values, in sequence, describe:
-
- TITLE: SPECIFICATION:
- dsx3M23 ANSI T1.107-1988
- dsx3SYNTRAN ANSI T1.107-1988
- dsx3CbitParity ANSI T1.107a-1989
- dsx3ClearChannel ANSI T1.102-1987
- e3Framed CCITT G.751
- e3Plcp ETSI T/NA(91)18."
- ::= { dsx3ConfigEntry 5 }
-
- dsx3LineCoding OBJECT-TYPE
- SYNTAX INTEGER {
- dsx3Other(1),
- dsx3B3ZS(2),
- e3HDB3(3)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This variable describes the variety of Zero Code
- Suppression used on this interface, which in turn
- affects a number of its characteristics.
-
- dsx3B3ZS and e3HDB3 refer to the use of specified
- patterns of normal bits and bipolar violations
- which are used to replace sequences of zero bits
- of a specified length."
- ::= { dsx3ConfigEntry 6 }
-
- dsx3SendCode OBJECT-TYPE
- SYNTAX INTEGER {
- dsx3SendNoCode(1),
- dsx3SendLineCode(2),
- dsx3SendPayloadCode(3),
- dsx3SendResetCode(4),
- dsx3SendDS1LoopCode(5),
- dsx3SendTestPattern(6)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
-
-
-
- Trunk MIB Working Group [Page 15]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- "This variable indicates what type of code is
- being sent across the DS3/E3 interface by the
- device. (These are optional for E3 interfaces.)
- The values mean:
-
- dsx3SendNoCode
- sending looped or normal data
-
- dsx3SendLineCode
- sending a request for a line loopback
-
- dsx3SendPayloadCode
- sending a request for a payload loopback
- (i.e., all DS1/E1s in a DS3/E3 frame)
-
- dsx3SendResetCode
- sending a loopback deactivation request
-
- dsx3SendDS1LoopCode
- requesting to loopback a particular DS1/E1
- within a DS3/E3 frame
-
- dsx3SendTestPattern
- sending a test pattern."
- ::= { dsx3ConfigEntry 7 }
-
- dsx3CircuitIdentifier OBJECT-TYPE
- SYNTAX DisplayString (SIZE (0..255))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This variable contains the transmission vendor's
- circuit identifier, for the purpose of
- facilitating troubleshooting."
- ::= { dsx3ConfigEntry 8 }
-
- dsx3LoopbackConfig OBJECT-TYPE
- SYNTAX INTEGER {
- dsx3NoLoop(1),
- dsx3PayloadLoop(2),
- dsx3LineLoop(3),
- dsx3OtherLoop(4)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This variable represents the loopback configuration
- of the DS3/E3 interface.
-
-
-
- Trunk MIB Working Group [Page 16]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- The values mean:
-
- dsx3NoLoop
- Not in the loopback state. A device that is
- not capable of performing a loopback on
- the interface shall always return this as
- it's value.
-
- dsx3PayloadLoop
- The received signal at this interface is looped
- through the device.
- Typically the received signal
- is looped back for retransmission after it has
- passed through the device's framing function.
-
- dsx3LineLoop
- The received signal at this interface does not
- go through the device (minimum penetration) but
- is looped back out.
-
- dsx3OtherLoop
- Loopbacks that are not defined here."
- ::= { dsx3ConfigEntry 9 }
-
- dsx3LineStatus OBJECT-TYPE
- SYNTAX INTEGER (1..1023)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "This variable indicates the
- Line Status of the interface.
- It contains loopback state information
- and failure state information.
- The dsx3LineStatus is a bit map represented
- as a sum, therefore,
- it can represent multiple failures
- and a loopback (see dsx3LoopbackConfig object
- for the type of loopback)
- simultaneously.
- The dsx3NoAlarm should be set if and only if
- no other flag is set.
-
- The various bit positions are:
- 1 dsx3NoAlarm No alarm present
- 2 dsx3RcvRAIFailure Receiving Yellow/Remote
- Alarm Indication
- 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote
- Alarm Indication
-
-
-
- Trunk MIB Working Group [Page 17]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- 8 dsx3RcvAIS Receiving AIS failure state
- 16 dsx3XmitAIS Transmitting AIS
- 32 dsx3LOF Receiving LOF failure state
- 64 dsx3LOS Receiving LOS failure state
- 128 dsx3LoopbackState Looping the received signal
- 256 dsx3RcvTestCode Receiving a Test Pattern
- 512 dsx3OtherFailure any line status not defined
- here"
- ::= { dsx3ConfigEntry 10 }
-
- dsx3TransmitClockSource OBJECT-TYPE
- SYNTAX INTEGER {
- loopTiming(1),
- localTiming(2),
- throughTiming(3)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "The source of Transmit Clock.
- is derived from the recovered receive clock of
- another DS3 interface."
- ::= { dsx3ConfigEntry 11 }
-
-
- -- the DS3/E3 Current
-
- -- The DS3/E3 current table contains various statistics being
- -- collected for the current 15 minute interval.
-
- dsx3CurrentTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3CurrentEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3/E3 Current table."
- ::= { ds3 6 }
-
- dsx3CurrentEntry OBJECT-TYPE
- SYNTAX Dsx3CurrentEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3/E3 Current table."
- INDEX { dsx3CurrentIndex }
- ::= { dsx3CurrentTable 1 }
-
-
-
-
-
- Trunk MIB Working Group [Page 18]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- Dsx3CurrentEntry ::=
- SEQUENCE {
- dsx3CurrentIndex
- INTEGER,
- dsx3CurrentPESs
- Gauge,
- dsx3CurrentPSESs
- Gauge,
- dsx3CurrentSEFSs
- Gauge,
- dsx3CurrentUASs
- Gauge,
- dsx3CurrentLCVs
- Gauge,
- dsx3CurrentPCVs
- Gauge,
- dsx3CurrentLESs
- Gauge,
- dsx3CurrentCCVs
- Gauge,
- dsx3CurrentCESs
- Gauge,
- dsx3CurrentCSESs
- Gauge
- }
-
- dsx3CurrentIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3/E3 interface to which this entry is
- applicable. The interface identified by a
- particular value of this index is the same
- interface as identified by the same value an
- dsx3LineIndex object instance."
- ::= { dsx3CurrentEntry 1 }
-
- dsx3CurrentPESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Errored Seconds, encountered by a DS3 interface in
- the current 15 minute interval."
- ::= { dsx3CurrentEntry 2 }
-
-
-
- Trunk MIB Working Group [Page 19]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- dsx3CurrentPSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Severely Errored Seconds, encountered by a DS3
- interface in the current 15 minute interval."
- ::= { dsx3CurrentEntry 3 }
-
- dsx3CurrentSEFSs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Severely Errored Framing Seconds, encountered by a
- DS3/E3 interface in the current 15 minute
- interval."
- ::= { dsx3CurrentEntry 4 }
-
- dsx3CurrentUASs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Unavailable Seconds, encountered by a DS3
- interface in the current 15 minute interval."
- ::= { dsx3CurrentEntry 5 }
-
- dsx3CurrentLCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of Line
- Coding Violations encountered by a DS3/E3
- interface in the current 15 minute interval."
- ::= { dsx3CurrentEntry 6 }
-
- dsx3CurrentPCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Coding Violations, encountered by a DS3 interface
-
-
-
- Trunk MIB Working Group [Page 20]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- in the current 15 minute interval."
- ::= { dsx3CurrentEntry 7 }
-
- dsx3CurrentLESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of Line Errored Seconds encountered by
- a DS3/E3 interface in the current 15 minute
- interval."
- ::= { dsx3CurrentEntry 8 }
-
- dsx3CurrentCCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Coding Violations encountered
- by a DS3 interface in the current 15 minute
- interval."
- ::= { dsx3CurrentEntry 9 }
-
- dsx3CurrentCESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Errored Seconds encountered
- by a DS3 interface in the current 15 minute
- interval."
- ::= { dsx3CurrentEntry 10 }
-
- dsx3CurrentCSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Severely Errored Seconds
- encountered by a DS3 interface in the current 15
- minute interval."
- ::= { dsx3CurrentEntry 11 }
-
-
- -- the DS3/E3 Interval
-
- -- The DS3/E3 Interval Table contains various statistics
- -- collected by each DS3/E3 Interface over the previous 24
-
-
-
- Trunk MIB Working Group [Page 21]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- -- hours of operation. The past 24 hours are broken into 96
- -- completed 15 minute intervals.
-
- dsx3IntervalTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3IntervalEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3/E3 Interval table."
- ::= { ds3 7 }
-
- dsx3IntervalEntry OBJECT-TYPE
- SYNTAX Dsx3IntervalEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3/E3 Interval table."
- INDEX { dsx3IntervalIndex, dsx3IntervalNumber }
- ::= { dsx3IntervalTable 1 }
-
- Dsx3IntervalEntry ::=
- SEQUENCE {
- dsx3IntervalIndex
- INTEGER,
- dsx3IntervalNumber
- INTEGER,
- dsx3IntervalPESs
- Gauge,
- dsx3IntervalPSESs
- Gauge,
- dsx3IntervalSEFSs
- Gauge,
- dsx3IntervalUASs
- Gauge,
- dsx3IntervalLCVs
- Gauge,
- dsx3IntervalPCVs
- Gauge,
- dsx3IntervalLESs
- Gauge,
- dsx3IntervalCCVs
- Gauge,
- dsx3IntervalCESs
- Gauge,
- dsx3IntervalCSESs
- Gauge
- }
-
-
-
-
- Trunk MIB Working Group [Page 22]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- dsx3IntervalIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3/E3 interface to which this entry is
- applicable. The interface identified by a
- particular value of this index is the same
- interface as identified by the same value an
- dsx3LineIndex object instance."
- ::= { dsx3IntervalEntry 1 }
-
- dsx3IntervalNumber OBJECT-TYPE
- SYNTAX INTEGER (1..96)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A number between 1 and 96, where 1 is the most
- recently completed 15 minute interval and 96 is
- the least recently completed 15 minutes interval
- (assuming that all 96 intervals are valid)."
- ::= { dsx3IntervalEntry 2 }
-
- dsx3IntervalPESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Errored Seconds, encountered by a DS3 interface in
- one of the previous 96, individual 15 minute,
- intervals."
- ::= { dsx3IntervalEntry 3 }
-
- dsx3IntervalPSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Severely Errored Seconds, encountered by a DS3
- interface in one of the previous 96, individual 15
- minute, intervals."
- ::= { dsx3IntervalEntry 4 }
-
- dsx3IntervalSEFSs OBJECT-TYPE
- SYNTAX Gauge
-
-
-
- Trunk MIB Working Group [Page 23]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Severely Errored Framing Seconds, encountered by a
- DS3/E3 interface in one of the previous 96,
- individual 15 minute, intervals."
- ::= { dsx3IntervalEntry 5 }
-
- dsx3IntervalUASs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Unavailable Seconds, encountered by a DS3
- interface in one of the previous 96, individual 15
- minute, intervals."
- ::= { dsx3IntervalEntry 6 }
-
- dsx3IntervalLCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of Line
- Coding Violations encountered by a DS3/E3
- interface in one of the previous 96, individual 15
- minute, intervals."
- ::= { dsx3IntervalEntry 7 }
-
- dsx3IntervalPCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Coding Violations, encountered by a DS3 interface
- in one of the previous 96, individual 15 minute,
- intervals."
- ::= { dsx3IntervalEntry 8 }
-
- dsx3IntervalLESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of Line Errored Seconds (BPVs or
-
-
-
- Trunk MIB Working Group [Page 24]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- illegal zero sequences) encountered by a DS3/E3
- interface in one of the previous 96, individual
- 15 minute, intervals."
- ::= { dsx3IntervalEntry 9 }
-
- dsx3IntervalCCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Coding Violations encountered
- by a DS3 interface in one of the previous 96,
- individual 15 minute, intervals."
- ::= { dsx3IntervalEntry 10 }
-
- dsx3IntervalCESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Errored Seconds encountered
- by a DS3 interface in one of the previous 96,
- individual 15 minute, intervals."
- ::= { dsx3IntervalEntry 11 }
-
- dsx3IntervalCSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Severely Errored Seconds
- encountered by a DS3 interface in one of the
- previous 96, individual 15 minute, intervals."
- ::= { dsx3IntervalEntry 12 }
-
-
- -- the DS3/E3 Total
-
- -- The DS3/E3 Total Table contains the cumulative sum of the
- -- various statistics for the 24 hour period preceding the
- -- current interval.
-
- dsx3TotalTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3TotalEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3/E3 Total table. 24 hour interval."
-
-
-
- Trunk MIB Working Group [Page 25]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- ::= { ds3 8 }
-
- dsx3TotalEntry OBJECT-TYPE
- SYNTAX Dsx3TotalEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3/E3 Total table."
- INDEX { dsx3TotalIndex }
- ::= { dsx3TotalTable 1 }
-
- Dsx3TotalEntry ::=
- SEQUENCE {
- dsx3TotalIndex
- INTEGER,
- dsx3TotalPESs
- Gauge,
- dsx3TotalPSESs
- Gauge,
- dsx3TotalSEFSs
- Gauge,
- dsx3TotalUASs
- Gauge,
- dsx3TotalLCVs
- Gauge,
- dsx3TotalPCVs
- Gauge,
- dsx3TotalLESs
- Gauge,
- dsx3TotalCCVs
- Gauge,
- dsx3TotalCESs
- Gauge,
- dsx3TotalCSESs
- Gauge
- }
-
- dsx3TotalIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3/E3 interface to which this entry is
- applicable. The interface identified by a
- particular value of this index is the same
- interface as identified by the same value an
- dsx3LineIndex object instance."
-
-
-
- Trunk MIB Working Group [Page 26]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- ::= { dsx3TotalEntry 1 }
-
- dsx3TotalPESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Errored Seconds, encountered by a DS3 interface in
- the previous 24 hour interval"
- ::= { dsx3TotalEntry 2 }
-
- dsx3TotalPSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Severely Errored Seconds, encountered by a DS3
- interface in the previous 24 hour interval."
- ::= { dsx3TotalEntry 3 }
-
- dsx3TotalSEFSs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Severely Errored Framing Seconds, encountered by a
- DS3/E3 interface in the previous 24 hour
- interval."
- ::= { dsx3TotalEntry 4 }
-
- dsx3TotalUASs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Unavailable Seconds, encountered by a DS3
- interface in the previous 24 hour interval."
- ::= { dsx3TotalEntry 5 }
-
- dsx3TotalLCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
-
-
-
- Trunk MIB Working Group [Page 27]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- "The counter associated with the number of Line
- Coding Violations encountered by a DS3/E3
- interface in the previous 24 hour interval."
- ::= { dsx3TotalEntry 6 }
-
- dsx3TotalPCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of P-bit
- Coding Violations, encountered by a DS3 interface
- in the previous 24 hour interval."
- ::= { dsx3TotalEntry 7 }
-
- dsx3TotalLESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of Line Errored Seconds (BPVs or
- illegal zero sequences) encountered by a DS3/E3
- interface in the previous 24 hour interval."
- ::= { dsx3TotalEntry 8 }
-
- dsx3TotalCCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Coding Violations encountered
- by a DS3 interface in the previous 24 hour
- interval."
- ::= { dsx3TotalEntry 9 }
-
- dsx3TotalCESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Errored Seconds encountered
- by a DS3 interface in the previous 24 hour
- interval."
- ::= { dsx3TotalEntry 10 }
-
- dsx3TotalCSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
-
-
-
- Trunk MIB Working Group [Page 28]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- STATUS mandatory
- DESCRIPTION
- "The number of C-bit Severely Errored Seconds
- encountered by a DS3 interface in the previous 24
- hour interval."
- ::= { dsx3TotalEntry 11 }
-
-
- -- The DS3 Far End Group
-
- -- Implementation of this group is optional for all systems
- -- that attach to a DS3 Interface.
- -- However, only C-bit Parity and SYNTRAN DS3 applications
- -- have the capability (option) of providing this information.
-
- -- The DS3 Far End Group consists of four tables:
- -- DS3 Far End Configuration
- -- DS3 Far End Current
- -- DS3 Far End Interval
- -- DS3 Far End Total
-
-
- -- The DS3 Far End Configuration Table contains
- -- configuration information
- -- reported in the C-bits from the remote end.
-
- dsx3FarEndConfigTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3FarEndConfigEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3 Far End Configuration table."
- ::= { ds3 9 }
-
- dsx3FarEndConfigEntry OBJECT-TYPE
- SYNTAX Dsx3FarEndConfigEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3 Far End Configuration table."
- INDEX { dsx3FarEndLineIndex }
- ::= { dsx3FarEndConfigTable 1 }
-
- Dsx3FarEndConfigEntry ::=
- SEQUENCE {
- dsx3FarEndLineIndex
- INTEGER,
- dsx3FarEndEquipCode
-
-
-
- Trunk MIB Working Group [Page 29]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- DisplayString,
- dsx3FarEndLocationIDCode
- DisplayString,
- dsx3FarEndFrameIDCode
- DisplayString,
- dsx3FarEndUnitCode
- DisplayString,
- dsx3FarEndFacilityIDCode
- DisplayString
- }
-
- dsx3FarEndLineIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3 interface
- to which this entry is applicable. The
- interface identified by a particular value of
- this index is the same interface as identified
- by the same value an dsx3LineIndex object
- instance."
- ::= { dsx3FarEndConfigEntry 1 }
-
- dsx3FarEndEquipCode OBJECT-TYPE
- SYNTAX DisplayString (SIZE (0..10))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This is the Far End Equipment Identification code
- that describes the specific piece of equipment.
- It is sent within the Path
- Identification Message."
- ::= { dsx3FarEndConfigEntry 2 }
-
- dsx3FarEndLocationIDCode OBJECT-TYPE
- SYNTAX DisplayString (SIZE (0..11))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This is the Far End Location Identification code
- that describes the specific location of the
- equipment.
- It is sent within the Path
- Identification Message."
- ::= { dsx3FarEndConfigEntry 3 }
-
-
-
-
- Trunk MIB Working Group [Page 30]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- dsx3FarEndFrameIDCode OBJECT-TYPE
- SYNTAX DisplayString (SIZE (0..10))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This is the Far End Frame Identification code
- that identifies where the equipment is located
- within a building at a given location.
- It is sent within the Path
- Identification Message."
- ::= { dsx3FarEndConfigEntry 4 }
-
- dsx3FarEndUnitCode OBJECT-TYPE
- SYNTAX DisplayString (SIZE (0..6))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This is the Far End code
- that identifies the equipment location within a bay.
- It is sent within the Path
- Identification Message."
- ::= { dsx3FarEndConfigEntry 5 }
-
- dsx3FarEndFacilityIDCode OBJECT-TYPE
- SYNTAX DisplayString (SIZE (0..38))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "This code identifies a specific Far End DS3 path.
- It is sent within the Path
- Identification Message."
- ::= { dsx3FarEndConfigEntry 6 }
-
-
- -- The DS3 Far End Current
-
- -- The DS3 Far End Current table contains various statistics
- -- being collected for the current 15 minute interval.
- -- The statistics are collected from the far end block error
- -- code within the C-bits.
-
- dsx3FarEndCurrentTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3FarEndCurrentEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3 Far End Current table."
- ::= { ds3 10 }
-
-
-
- Trunk MIB Working Group [Page 31]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- dsx3FarEndCurrentEntry OBJECT-TYPE
- SYNTAX Dsx3FarEndCurrentEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3 Far End Current table."
- INDEX { dsx3FarEndCurrentIndex }
- ::= { dsx3FarEndCurrentTable 1 }
-
- Dsx3FarEndCurrentEntry ::=
- SEQUENCE {
- dsx3FarEndCurrentIndex
- INTEGER,
- dsx3FarEndTimeElapsed
- INTEGER,
- dsx3FarEndValidIntervals
- INTEGER,
- dsx3FarEndCurrentCESs
- Gauge,
- dsx3FarEndCurrentCSESs
- Gauge,
- dsx3FarEndCurrentCCVs
- Gauge,
- dsx3FarEndCurrentUASs
- Gauge
- }
-
- dsx3FarEndCurrentIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3 interface
- to which this entry is applicable. The interface
- identified by a particular value of this index is
- the same interface as identified by the same value
- an dsx3LineIndex object instance."
- ::= { dsx3FarEndCurrentEntry 1 }
-
- dsx3FarEndTimeElapsed OBJECT-TYPE
- SYNTAX INTEGER (0..899)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of seconds that have elapsed since the
- beginning of the far end current error-measurement
- period."
-
-
-
- Trunk MIB Working Group [Page 32]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- ::= { dsx3FarEndCurrentEntry 2 }
-
- dsx3FarEndValidIntervals OBJECT-TYPE
- SYNTAX INTEGER (0..96)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of previous far end intervals for
- which valid data was collected. The value will be
- 96 unless the interface was brought online within
- the last 24 hours, in which case the value will be
- the number of complete 15 minute far end intervals
- since the interface has been online."
- ::= { dsx3FarEndCurrentEntry 3 }
-
- dsx3FarEndCurrentCESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of Far
- Far End C-bit Errored Seconds encountered by a DS3
- interface in the current 15 minute interval."
- ::= { dsx3FarEndCurrentEntry 4 }
-
- dsx3FarEndCurrentCSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End C-bit Severely Errored Seconds
- encountered by a DS3 interface in the current 15
- minute interval."
- ::= { dsx3FarEndCurrentEntry 5 }
-
- dsx3FarEndCurrentCCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End C-bit Coding Violations reported via
- the far end block error count
- encountered by a
- DS3 interface in the current 15 minute interval."
- ::= { dsx3FarEndCurrentEntry 6 }
-
-
-
-
- Trunk MIB Working Group [Page 33]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- dsx3FarEndCurrentUASs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End unavailable seconds
- encountered by a
- DS3 interface in the current 15 minute interval."
- ::= { dsx3FarEndCurrentEntry 7 }
-
-
- -- The DS3 Far End Interval
-
- -- The DS3 Far End Interval Table contains various statistics
- -- collected by each DS3 interface over the previous 24
- -- hours of operation. The past 24 hours are broken into 96
- -- completed 15 minute intervals.
-
- dsx3FarEndIntervalTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3FarEndIntervalEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3 Far End Interval table."
- ::= { ds3 11 }
-
- dsx3FarEndIntervalEntry OBJECT-TYPE
- SYNTAX Dsx3FarEndIntervalEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3 Far
- End Interval table."
- INDEX { dsx3FarEndIntervalIndex,
- dsx3FarEndIntervalNumber }
- ::= { dsx3FarEndIntervalTable 1 }
-
- Dsx3FarEndIntervalEntry ::=
- SEQUENCE {
- dsx3FarEndIntervalIndex
- INTEGER,
- dsx3FarEndIntervalNumber
- INTEGER,
- dsx3FarEndIntervalCESs
- Gauge,
- dsx3FarEndIntervalCSESs
- Gauge,
-
-
-
- Trunk MIB Working Group [Page 34]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- dsx3FarEndIntervalCCVs
- Gauge,
- dsx3FarEndIntervalUASs
- Gauge
- }
-
- dsx3FarEndIntervalIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3 interface
- to which this entry is applicable. The
- interface identified by a particular value of
- this index is the same interface as identified
- by the same value an dsx3LineIndex object
- instance."
- ::= { dsx3FarEndIntervalEntry 1 }
-
- dsx3FarEndIntervalNumber OBJECT-TYPE
- SYNTAX INTEGER (1..96)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A number between 1 and 96, where 1 is the most
- recently completed 15 minute interval and 96 is
- the least recently completed 15 minutes
- interval (assuming that all 96 intervals are
- valid)."
- ::= { dsx3FarEndIntervalEntry 2 }
-
- dsx3FarEndIntervalCESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End C-bit Errored Seconds encountered
- by a DS3 interface in one of the previous 96,
- individual 15 minute, intervals."
- ::= { dsx3FarEndIntervalEntry 3 }
-
- dsx3FarEndIntervalCSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
-
-
-
- Trunk MIB Working Group [Page 35]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- "The counter associated with the number of
- Far End C-bit Severely Errored Seconds
- encountered by a DS3 interface in one of the
- previous 96, individual 15 minute, intervals."
- ::= { dsx3FarEndIntervalEntry 4 }
-
- dsx3FarEndIntervalCCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End C-bit Coding Violations reported via
- the far end block error count
- encountered by a
- DS3 interface in one of the previous 96,
- individual 15 minute, intervals."
- ::= { dsx3FarEndIntervalEntry 5 }
-
- dsx3FarEndIntervalUASs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End unavailable seconds
- encountered by a
- DS3 interface in one of the previous 96,
- individual 15 minute, intervals."
- ::= { dsx3FarEndIntervalEntry 6 }
-
-
- -- The DS3 Far End Total
-
- -- The DS3 Far End Total Table contains the cumulative sum
- -- of the various statistics for the 24 hour period preceding
- -- the current interval.
-
- dsx3FarEndTotalTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3FarEndTotalEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3 Far End Total table. 24 hour interval."
- ::= { ds3 12 }
-
- dsx3FarEndTotalEntry OBJECT-TYPE
- SYNTAX Dsx3FarEndTotalEntry
-
-
-
- Trunk MIB Working Group [Page 36]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3 Far End Total table."
- INDEX { dsx3FarEndTotalIndex }
- ::= { dsx3FarEndTotalTable 1 }
-
- Dsx3FarEndTotalEntry ::=
- SEQUENCE {
- dsx3FarEndTotalIndex
- INTEGER,
- dsx3FarEndTotalCESs
- Gauge,
- dsx3FarEndTotalCSESs
- Gauge,
- dsx3FarEndTotalCCVs
- Gauge,
- dsx3FarEndTotalUASs
- Gauge
- }
-
- dsx3FarEndTotalIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3 interface
- to which this entry is applicable. The interface
- identified by a particular value of this index is
- the same interface as identified by the same value
- an dsx3LineIndex object instance."
- ::= { dsx3FarEndTotalEntry 1 }
-
- dsx3FarEndTotalCESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of Far
- End C-bit Errored Seconds encountered by a DS3
- interface in the previous 24 hour interval."
- ::= { dsx3FarEndTotalEntry 2 }
-
- dsx3FarEndTotalCSESs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
-
-
-
- Trunk MIB Working Group [Page 37]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- DESCRIPTION
- "The counter associated with the number of
- Far End C-bit Severely Errored Seconds
- encountered by a DS3 interface in the previous 24
- hour interval."
- ::= { dsx3FarEndTotalEntry 3 }
-
- dsx3FarEndTotalCCVs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End C-bit Coding Violations reported via the
- far end block error count
- encountered by a
- DS3 interface in the previous 24 hour interval."
- ::= { dsx3FarEndTotalEntry 4 }
-
- dsx3FarEndTotalUASs OBJECT-TYPE
- SYNTAX Gauge
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The counter associated with the number of
- Far End unavailable seconds
- encountered by a
- DS3 interface in the previous 24 hour interval."
- ::= { dsx3FarEndTotalEntry 5 }
-
-
- -- the DS3/E3 Fractional Group
-
- -- Implementation of this group is optional. It is designed
- -- for those systems dividing a DS3/E3 into channels
- -- containing different data streams that are of local
- -- interest.
-
- -- The DS3/E3 fractional table identifies which DS3/E3
- -- channels associated with a CSU are being used to
- -- support a logical interface, i.e., an entry in the
- -- interfaces table from the Internet-standard MIB.
-
- -- For example, consider a DS3 device with 4 high speed links
- -- carrying router traffic, a feed for voice, a feed for
- -- video, and a synchronous channel for a non-routed
- -- protocol.
- -- We might describe the allocation of channels, in the
-
-
-
- Trunk MIB Working Group [Page 38]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- -- dsx3FracTable, as follows:
-
- -- dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4
- -- dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6
- -- dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6
- -- dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6
- -- dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6
- -- dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6
- -- dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6
- -- dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6
- -- dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6
- -- dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6
- -- dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6
- -- dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6
- -- dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6
- -- dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6
-
- -- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and
- -- dsx3ClearChannel there are 28 legal channels, numbered 1
- -- through 28.
-
- -- For e3Framed there are 16 legal channels,
- -- numbered 1 through 16. The channels (1..16) correspond
- -- directly to the equivalently numbered time-slots.
-
- dsx3FracTable OBJECT-TYPE
- SYNTAX SEQUENCE OF Dsx3FracEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The DS3 Fractional table."
- ::= { ds3 13 }
-
- dsx3FracEntry OBJECT-TYPE
- SYNTAX Dsx3FracEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the DS3 Fractional table."
- INDEX { dsx3FracIndex, dsx3FracNumber }
- ::= { dsx3FracTable 1 }
-
- Dsx3FracEntry ::=
- SEQUENCE {
- dsx3FracIndex
- INTEGER,
- dsx3FracNumber
- INTEGER,
-
-
-
- Trunk MIB Working Group [Page 39]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- dsx3FracIfIndex
- INTEGER
- }
-
-
- dsx3FracIndex OBJECT-TYPE
- SYNTAX INTEGER (1..'7fffffff'h)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The index value which uniquely identifies the
- DS3 interface to which this entry is applicable
- The interface identified by a particular
- value of this index is the same interface as
- identified by the same value an dsx3LineIndex
- object instance."
- ::= { dsx3FracEntry 1 }
-
- dsx3FracNumber OBJECT-TYPE
- SYNTAX INTEGER (1..31)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The channel number for this entry."
- ::= { dsx3FracEntry 2 }
-
- dsx3FracIfIndex OBJECT-TYPE
- SYNTAX INTEGER (1..'7fffffff'h)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "An index value that uniquely identifies an
- interface. The interface identified by a particular
- value of this index is the same interface
- as identified by the same value an ifIndex
- object instance. If no interface is currently using
- a channel, the value should be zero. If a
- single interface occupies more than one time
- slot, that ifIndex value will be found in multiple
- time slots."
- ::= { dsx3FracEntry 3 }
-
-
-
- END
-
-
-
-
-
-
- Trunk MIB Working Group [Page 40]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- 5. Acknowledgments
-
- This document was produced by the Trunk MIB Working Groups:
-
- Tracy Cox Bellcore
- Fred Baker Advanced Computer Communications
- James Watt Newbridge
- Bill Versteeg Versteeg Codeworks
- Steve Buchko Newbridge
- Greg Calmainis Newbridge
- Kaj Tesink Bellcore
- Al Bryenton Bell Northern Research
- Tom Easterday CIC
- John Labbe Merit Corporation
- Chris Sullivan Gandalf Ltd
- Grant Hall Gandalf Ltd
- John Guerrero Digital Link
- Rich Bradford BBN
- Kurt Luoto Digital Link
- Myron Hattig Kentrox
- Ed Pring IBM
- Larry Marks IBM
- Kurt Hall Clear Communications Corp.
- Jason Perreault Coral Network Corp.
- Paul Farah T3plus
- George Kajos Coral Network Corp.
-
- 6. References
-
- [1] Cerf, V., "IAB Recommendations for the Development of Internet
- Network Management Standards", RFC 1052, NRI, April 1988.
-
- [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
- Group", RFC 1109, NRI, August 1989.
-
- [3] Rose M., and K. McCloghrie, "Structure and Identification of
- Management Information for TCP/IP-based internets", STD 16, RFC
- 1155, Performance Systems International, Hughes LAN Systems, May
- 1990.
-
- [4] McCloghrie K., and M. Rose, "Management Information Base for
- Network Management of TCP/IP-based internets", RFC 1156, Hughes
- LAN Systems, Performance Systems International, May 1990.
-
- [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
- Network Management Protocol", STD 15, RFC 1157, SNMP Research,
- Performance Systems International, Performance Systems
- International, MIT Laboratory for Computer Science, May 1990.
-
-
-
- Trunk MIB Working Group [Page 41]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- [6] McCloghrie K., and M. Rose, Editors, "Management Information Base
- for Network Management of TCP/IP-based internets", STD 17, RFC
- 1213, Performance Systems International, March 1991.
-
- [7] Information processing systems - Open Systems Interconnection -
- Specification of Abstract Syntax Notation One (ASN.1),
- International Organization for Standardization, International
- Standard 8824, December 1987.
-
- [8] Information processing systems - Open Systems Interconnection -
- Specification of Basic Encoding Rules for Abstract Notation One
- (ASN.1), International Organization for Standardization,
- International Standard 8825, December 1987.
-
- [9] American National Standard for Telecommunications - Digital
- Hierarchy - Electrical Interfaces, ANSI T1.102- 1987.
-
- [10] American National Standard for Telecommunications - Digital
- Hierarchy - Formats Specification, ANSI T1.107- 1988.
-
- [10a] ANSI T1.107a-1990.
-
- [11] American National Standard for Telecommunications - Carrier-to-
- Customer Installation - DS3 Metallic Interface, ANSI T1.404-1989.
-
- [12] American National Standard for Telecommunications -- Layer 1 In-
- Service Digital Transmission Performance Monitoring T1M1/92-0xx,
- T1M1.3/92-005R1, April 1992.
-
- [13] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
- STD 16, RFC 1212, Performance Systems International, Hughes LAN
- Systems, March 1991.
-
- [14] CCITT - Digital Multiplex Equipment Operating at the Third Order
- Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264
- Kbit/s and Using Positive Justification, G.751.
-
- [15] European Telecommunications Standards Institute -- ETS "34M" --
- Metropolitan Area Network Physical Convergence Layer Procedure
- for 34.368 Megabits per Second, T/NA(91)18, May 1991.
-
-
-
-
-
-
-
-
-
-
-
- Trunk MIB Working Group [Page 42]
-
- RFC 1407 DS3/E3 MIB January 1993
-
-
- 7. Security Considerations
-
- Security issues are not discussed in this memo.
-
- 8. Authors' Addresses
-
- Tracy A. Cox
- Bell Communications Research
- 331 Newman Springs Road
- P.O. Box 7020
- Red Bank, NJ 07701-7020
-
- Phone: (908) 758-2107
- EMail: tacox@mail.bellcore.com
-
-
- Kaj Tesink
- Bell Communications Research
- 331 Newman Springs Road
- P.O. Box 7020
- Red Bank, NJ 07701-7020
-
- Phone: (908) 758-5254
- EMail: kaj@cc.bellcore.com
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Trunk MIB Working Group [Page 43]
-
-